When measuring the open-circuit voltage (Voc) of a PV string, the measured value is lower than the temperature-corrected expected value. What is the most likely cause?

Practise this Solar PV NABCEP question free, then download the PDF, watch the video walkthrough, or unlock timed mock exams for the full web bank.
Download PDFWatch video
Multiple choice — select the best answer
✓ Correct answer: B. One or more modules in the string are bypassed or shaded A string Voc lower than expected typically indicates a module is being bypassed (by its own bypass diode due to shading or damage) or a module is missing from the string, reducing the series voltage.