A residential lawn irrigation system supplied by potable water and using chemical fertilizer injection would be classified as which hazard level?

Practise this Journeyman Plumber 2 question free, then download the PDF, watch the video walkthrough, or unlock timed mock exams for the full web bank.
Download PDFWatch video
Multiple choice — select the best answer
✓ Correct answer: C. High hazard — chemical injection creates a potential health hazard The introduction of chemical fertilizers or pesticides through an injector connected to the potable supply creates a high-hazard cross-connection, regardless of the residential setting. This requires at minimum a reduced pressure principle backflow preventer.